Dimensional and assembly data for M16 Hex Flange Bolts to ISO 1665 / DIN 6921. Includes head size and width across flats, clearance-hole and tapping-drill diameters, tightening torque per property class, and the sizes to step up or down to when the joint requires it.
M16 Dimensional Row (ISO 1665 / DIN 6921)
| Size | Pitch (mm) | Flange diameter dc (mm) | Head height k (mm) | Width across flats s (mm) | Reference standard |
|---|---|---|---|---|---|
| M16 | 2.0 | 34.5 | 14.1 | 24.0 | ISO 1665 / DIN 6921 |
Spanner & Drive for M16 Hex Flange Bolts
M16 Hex Flange Bolts have a width across flats of 24.0 mm — fit a 24.0 mm open-ended spanner or socket. Use a 6-point socket for tight clearances and to reduce rounding; for repeated assembly choose a torque wrench so the joint preload is repeatable.
Hole Sizes for M16
| Coarse-thread pitch (ISO 724) | 2 mm |
|---|---|
| Through-hole / clearance (ISO 273 medium) | 17.5 mm |
| Tapping drill, coarse thread | 14 mm |
Tightening Torque for M16
| Class 8.8 (dry, ~µ 0.125) | ≈ 210 Nm |
|---|---|
| Class 10.9 (dry, ~µ 0.125) | ≈ 295 Nm |
| Class 12.9 (dry, ~µ 0.125) | ≈ 355 Nm |
Indicative dry-joint values. Lubrication can lower the required torque by 15–25%. Always confirm against the joint design, especially when going up a strength class.
Proof Load & Strength for M16
| Tensile stress area As (ISO 898-1) | 157 mm² |
|---|---|
| Proof load, class 8.8 | 91 kN |
| Proof load, class 10.9 | 130 kN |
| Proof load, class 12.9 | 152 kN |
| Min. ultimate tensile, class 8.8 | 126 kN |
Proof load = stress area × proof stress per ISO 898-1. Design joints so the working preload stays below the proof load of the selected class.
Common Applications for M16 Hex Flange Bolts
M16 Hex Flange Bolts are commonly specified for medium-duty structural connections, automotive sub-frames and equipment chassis.
Installation Tips for M16 Hex Flange Bolts
- Use a 6-point socket where access allows — 12-point sockets are more prone to rounding the corners on smaller sizes.
- On flanged or serrated variants, do NOT add a separate flat washer — the flange already spreads the load and the washer can defeat the locking serrations.
When to Step Up or Down from M16
When the joint preload approaches the proof load of M16 class 8.8, step up to M20 class 8.8 (or move to M16 class 10.9). When the joint is over-specified, M12 often saves weight and cost without losing the safety margin.