Dimensional data for M36 Thin Hex Nut to GB/T 6172.1 / ISO 4035, with the drive and the installation notes for this type. Values are taken from the governing standard rather than from a general machine-thread table, because this type is not selected on one.
M36 Dimensional Row (GB/T 6172.1 / ISO 4035)
| Size | Pitch (mm) | Width across flats s (mm) | Width across corners e (mm) | Nut height m (mm) | Reference standard |
|---|---|---|---|---|---|
| M36 | 4.0 | 55.0 | 60.79 | 18.0 | ISO 4035 / GB/T 6172 |
Spanner & Drive for M36 Thin Hex Nut — GB/T 6172.1 / ISO 4035 (Series 055)
M36 Thin Hex Nut — GB/T 6172.1 / ISO 4035 (Series 055) have a width across flats of 55.0 mm — fit a 55.0 mm open-ended spanner or socket. Use a 6-point socket for tight clearances and to reduce rounding; for repeated assembly choose a torque wrench so the joint preload is repeatable.
Tightening Torque for M36
| Class 8.8 (dry, ~µ 0.125) | ≈ 2450 Nm |
|---|---|
| Class 10.9 (dry, ~µ 0.125) | ≈ 3450 Nm |
| Class 12.9 (dry, ~µ 0.125) | ≈ 4150 Nm |
Indicative dry-joint values. Lubrication can lower the required torque by 15–25%. Always confirm against the joint design, especially when going up a strength class.
Proof Load & Strength for M36
| Tensile stress area As (ISO 898-1) | 817 mm² |
|---|---|
| Proof load, class 8.8 | 490 kN |
| Proof load, class 10.9 | 678 kN |
| Proof load, class 12.9 | 792 kN |
| Min. ultimate tensile, class 8.8 | 654 kN |
Proof load = stress area × proof stress per ISO 898-1. Design joints so the working preload stays below the proof load of the selected class.
Common Applications for M36 Thin Hex Nut — GB/T 6172.1 / ISO 4035 (Series 055)
M36 Thin Hex Nut — GB/T 6172.1 / ISO 4035 (Series 055) are commonly specified for structural joints, flange connections and heavy equipment foundations.
Installation Tips for M36 Thin Hex Nut — GB/T 6172.1 / ISO 4035 (Series 055)
- Use a 6-point socket where access allows — 12-point sockets are more prone to rounding the corners on smaller sizes.
- On flanged or serrated variants, do NOT add a separate flat washer — the flange already spreads the load and the washer can defeat the locking serrations.
- At M36 the stretch in the bolt becomes the controlling factor — for critical joints, use angle-controlled or stretch-controlled tightening instead of pure torque.
Mating Parts for M36
Pair M36 with the matching M36 bolt or screw, plus a M36 flat washer where required to distribute load on softer materials.