Skip to content

Bolts · ISO 4014 / ISO 4017

Grade 8.8 Steel Hex Bolts

Specifying Hex Bolts in Grade 8.8 Steel pairs the dimensional form of Hex Bolts (ISO 4014 / ISO 4017) with the engineering properties of Grade 8.8 Steel. This page explains when to choose the grade, how it behaves in service, and which grades to compare it against.

Why Choose Grade 8.8 Steel for Hex Bolts

The workhorse medium-carbon alloy grade for structural joints. For hex bolts, this matters when requires plating (zinc) for corrosion protection is the primary requirement.

Mechanical & Physical Properties

Grade designationclass 8.8
Magnetic responseMagnetic
Service temperatureup to approx. +300 °C
Corrosion characteristicRequires plating (zinc) for corrosion protection

Galvanic & Galling Considerations

For hex bolts in steel, the dominant compatibility issue is hydrogen embrittlement at high property classes (10.9 and above) when electroplated. Plating must be followed by an appropriate baking treatment, or a non-electroplated finish (mechanical zinc, zinc flake) should be substituted.

Comparable Grades

For Hex Bolts, class 10.9 or 12.9 is the comparable strength step. Move up when the joint preload approaches the proof load of the current class; move down when the joint is over-specified. For corrosion-critical service, switch to stainless A2 or A4.

Sizes of Hex Bolts Available in Grade 8.8 Steel

SizePitch coarse (mm)Width across flats s (mm)Width across corners e min (mm)Head height k nom (mm)Nominal diameter d (mm)Reference standardNotes
M10.252.52.710.71.0ISO 4017Fully threaded
M1.20.253.03.280.81.2ISO 4017Fully threaded
M1.40.33.03.280.91.4ISO 4017Fully threaded
M1.60.353.23.481.11.6ISO 4014/4017Fully threaded
M20.44.04.321.42.0ISO 4014/4017Fully threaded
M2.50.455.05.451.72.5ISO 4014/4017Fully threaded
M30.55.56.012.03.0ISO 4014/4017Fully threaded
M40.77.07.662.84.0ISO 4014/4017Fully threaded
M50.88.08.793.55.0ISO 4014/4017Fully threaded
M61.010.011.054.06.0ISO 4014/4017Fully threaded
M81.2513.014.385.38.0ISO 4014/4017Fully threaded
M101.516.017.776.410.0ISO 4014/4017Fully threaded
M121.7518.020.037.512.0ISO 4014/4017Partial / fully threaded
M142.021.023.368.814.0ISO 4014/4017Partial / fully threaded
M162.024.026.7510.016.0ISO 4014/4017Partial / fully threaded
M182.527.030.1411.518.0ISO 4014/4017Partial / fully threaded
M202.530.033.5312.520.0ISO 4014/4017Partial / fully threaded
M222.532.035.7214.022.0ISO 4014/4017Partial / fully threaded
M243.036.039.9815.024.0ISO 4014/4017Partial / fully threaded
M273.041.045.217.027.0ISO 4014/4017Partial / fully threaded
M303.546.050.8518.730.0ISO 4014/4017Partial / fully threaded
M333.550.055.3721.033.0ISO 4014/4017Partial / fully threaded
M364.055.060.7922.536.0ISO 4014/4017Partial / fully threaded
M394.060.066.4425.039.0ISO 4014/4017Partial / fully threaded
M424.565.071.326.042.0ISO 4014/4017Partial / fully threaded
M454.570.076.9528.045.0ISO 4014/4017Partial / fully threaded
M485.075.082.630.048.0ISO 4014/4017Partial / fully threaded
M525.080.088.2533.052.0ISO 4014/4017Partial / fully threaded
M565.585.093.5635.056.0ISO 4014Partial / fully threaded
M605.590.099.2138.060.0ISO 4014Partial / fully threaded

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ISO 4014 / ISO 4017)

SizePitch coarse (mm)Width across flats s (mm)Width across corners e min (mm)Head height k nom (mm)Nominal diameter d (mm)Reference standardNotes
M10.252.52.710.71.0ISO 4017Fully threaded
M1.20.253.03.280.81.2ISO 4017Fully threaded
M1.40.33.03.280.91.4ISO 4017Fully threaded
M1.60.353.23.481.11.6ISO 4014/4017Fully threaded
M20.44.04.321.42.0ISO 4014/4017Fully threaded
M2.50.455.05.451.72.5ISO 4014/4017Fully threaded
M30.55.56.012.03.0ISO 4014/4017Fully threaded
M40.77.07.662.84.0ISO 4014/4017Fully threaded
M50.88.08.793.55.0ISO 4014/4017Fully threaded
M61.010.011.054.06.0ISO 4014/4017Fully threaded
M81.2513.014.385.38.0ISO 4014/4017Fully threaded
M101.516.017.776.410.0ISO 4014/4017Fully threaded
M121.7518.020.037.512.0ISO 4014/4017Partial / fully threaded
M142.021.023.368.814.0ISO 4014/4017Partial / fully threaded
M162.024.026.7510.016.0ISO 4014/4017Partial / fully threaded
M182.527.030.1411.518.0ISO 4014/4017Partial / fully threaded
M202.530.033.5312.520.0ISO 4014/4017Partial / fully threaded
M222.532.035.7214.022.0ISO 4014/4017Partial / fully threaded
M243.036.039.9815.024.0ISO 4014/4017Partial / fully threaded
M273.041.045.217.027.0ISO 4014/4017Partial / fully threaded
M303.546.050.8518.730.0ISO 4014/4017Partial / fully threaded
M333.550.055.3721.033.0ISO 4014/4017Partial / fully threaded
M364.055.060.7922.536.0ISO 4014/4017Partial / fully threaded
M394.060.066.4425.039.0ISO 4014/4017Partial / fully threaded
M424.565.071.326.042.0ISO 4014/4017Partial / fully threaded
M454.570.076.9528.045.0ISO 4014/4017Partial / fully threaded
M485.075.082.630.048.0ISO 4014/4017Partial / fully threaded
M525.080.088.2533.052.0ISO 4014/4017Partial / fully threaded
M565.585.093.5635.056.0ISO 4014Partial / fully threaded
M605.590.099.2138.060.0ISO 4014Partial / fully threaded
M646.095.0104.8640.064.0ISO 4014Partial / fully threaded

Frequently Asked Questions

Is Grade 8.8 Steel prone to hydrogen embrittlement?

Class 10.9 and above can be susceptible to hydrogen embrittlement when electroplated. Specify post-plating baking, or use mechanical-zinc / zinc-flake finishes which avoid the cathodic plating step.

Which finish is best for outdoor Hex Bolts?

For outdoor service in steel, hot-dip galvanizing gives the longest life; zinc-flake (Geomet/Delta-Tone family) gives a thinner film with excellent salt-spray performance; standard zinc plating is the lowest-cost option for general indoor / shielded outdoor use.

What's the service temperature limit for Grade 8.8 Steel?

The practical service range is up to approx. +300 °C.

Can Grade 8.8 Steel replace stainless steel structurally?

No — stainless A2/A4 cannot match class 10.9 / 12.9 strength. Stainless is selected for corrosion, not raw strength.

How do I request a quotation?

Use the technical drawing on this page to pick the exact configuration, then submit it with the quote form. We respond within one business day.