| Model NO. | OMC-120WSH |
| Type | Water-Cooled |
| Cooling Method | Screw |
| Unit Structure | Integral |
| Selected Voltage | 380V/50HZ |
| Compressor Number | 1 |
| Noise Level | Low |
| Application Fields | Plastic |
| Application Machine | Combination machine |
| Condition | New |
| Cooling Capacity | 80 Ton/ 250kw |
| Compressor | Semi-Hermetic |
| Controller | LCD Touch / Siemes PLC |
| Refrigerant | R22/R407c/R404A |
| Transport Package | Plywood |
| Specification | 80 Ton |
| Origin | China |
| HS Code | 8418692090 |
| Production Capacity | 500 |
| Customization | Available |
| After-sales Service | 7X 24 Hours |
| Warranty | 15 Months |
| Shipping Cost | Contact the supplier about freight and estimated delivery time. |
| Condenser | In a water-cooled system, the condenser is responsible for transferring heat from the refrigerant to the water. It is typically a shell-and-tube heat exchanger where the hot refrigerant gas is condensed into a liquid. |
| Evaporator | The evaporator facilitates heat exchange between the chilled water and the refrigerant. Heat is absorbed from the process water or the industrial equipment, causing the refrigerant to evaporate and cool down the water. |
| Expansion Device | The expansion device, such as a thermal expansion valve or an electronic expansion valve, controls the flow and pressure of the refrigerant as it enters the evaporator. |
| Water Circulation System | A water pump is used to circulate the chilled water from the evaporator to the process equipment or industrial application, and then return the heated water back to the condenser for cooling. |
| Control System | The control system manages the operation of the chiller system, including temperature control, pressure control, and safety features. It ensures efficient and reliable performance while maintaining precise temperature conditions. |
| Precise Temperature Control | The system should be capable of maintaining tight temperature control within a desired range to ensure process stability and product quality. |
| Energy Efficiency | The chiller system should be designed with energy-efficient components and features, such as variable speed drives, to optimize energy consumption and reduce operating costs. |
| Reliability and Durability | Industrial chillers should be built with durable materials and reliable components to ensure long-term, uninterrupted operation even under demanding conditions. |
| Easy Maintenance | The chiller system should allow for easy access to components for routine maintenance tasks such as cleaning, inspection, and part replacement. |
| Safety Features | The system should incorporate safety features such as high- and low-pressure protection, temperature alarms, and automatic shutdown mechanisms to protect the equipment and prevent any potential hazards. |
| Small space occupied | multiple components are integrated into one unit, the unit is smaller in size and takes up less space, and is suitable for places with limited space. |
| Convenient installation | Since multiple components are integrated into one unit, it is more convenient to install and easier to maintain and maintain. |
| Energy saving and environmental protection | The optimized unit design and the adoption of new energy-saving technology enable the water-cooled screw integrated chiller to make full use of energy, save energy and protect the environment. |
| Stable operation | The screw compressor has a high compression ratio and low operating speed, stable refrigeration effect, low noise, and stable and reliable operation. |
| Precise control | Equipped with an advanced automated control system, precise control and management of the refrigeration system can be achieved to ensure the stable operation of the air conditioning system. |
| The working principle of the water cooled screw chiller is | When the unit is refrigerated, the compressor sucks the low-temperature and low-pressure refrigerant in the evaporator into the cylinder. After the compressor performs work, the refrigerant vapor is compressed into high-temperature and high-pressure gas. |
| Compressor features | •New screw type compressor with 20%-30% higher in efficiency. |
| Control operation system | •SIEMENS PLC program control system, human-computer interface with big LED touch panel, running state displaying in multi-language, and self-diagnosis for easy operation and supervision. |
| Completely safety protection function | •Multi-safety protection by high and low pressure, compressor overheating, overloading, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating and anti-freezing. |
| Air Conditioning | Water-cooled screw chillers are often used in large commercial buildings, such as shopping malls, hotels, office complexes, and hospitals, to provide central air conditioning. They can cool the air and maintain a comfortable indoor temperature in a cost-effective and energy-efficient manner. |
| Industrial Processes | Many industrial processes require precise temperature control to ensure product quality, improve process efficiency, or maintain equipment operation. Water-cooled screw chillers are utilized in industries such as food and beverage, pharmaceuticals, plastics, chemical processing, printing, and automotive manufacturing to cool process equipment and control temperatures during production. |
| Data Centers | Data centers generate a significant amount of heat due to the high-density racks of servers and networking equipment. Water-cooled screw chillers are used to remove heat from data center facilities and maintain proper cooling for the equipment, ensuring optimal performance and preventing overheating. |
| Power Generation | Power plants and electricity generation facilities often need cooling systems to remove heat from equipment, such as gas turbines, steam turbines, and generators. Water-cooled screw chillers are employed to extract heat and maintain the operating temperature of critical components, ensuring efficient and reliable power generation. |
| Refrigeration | Water-cooled screw chillers also find applications in refrigeration systems, such as cold storage warehouses, food processing facilities, and supermarkets. They provide the necessary cooling to preserve perishable goods and maintain low temperatures for storage and distribution. |
| Category | Other Machine & Custom Screws |