Skip to content
Nuts · GB/T 6187 / DIN 6927 / ASME B18.2.2 · Application guide

What Are All-Metal Hex Flange Lock Nuts Used For?

Typical applications, the industries that specify all-metal hex flange lock nuts, and how to choose the right size, material and finish for the joint.

All-Metal Hex Flange Lock Nuts are used for the clamped counter-face of a bolted joint. They are manufactured to GB/T 6187 / DIN 6927 / ASME B18.2.2, and the choice of size, property class and finish is driven by the load in the joint and the environment it sits in.

Primary duty
The clamped counter-face of a bolted joint
Governing standard
GB/T 6187 / DIN 6927 / ASME B18.2.2
Nominal diameter range
8 mm to 12 mm
Category
Nuts

Application notes are general engineering guidance. Verify the property class and any approval requirement against your own design calculation.

What Are All-Metal Hex Flange Lock Nuts Used For? application image

All-Metal Hex Flange Lock Nuts are selected when an assembly calls for the clamped counter-face of a bolted joint. This application guide to the GB/T 6187 / DIN 6927 / ASME B18.2.2 type covers concrete end-uses, the specification checklist, correct installation, and where an alternative fastener performs better. Stocked across roughly 8 mm to 12 mm, they cover general to heavy-duty work.

Typical Applications for All-Metal Hex Flange Lock Nuts

The most common settings where these are specified:

  • Fabrication & metalwork: bench and on-site assembly of steel frames, enclosures and weldments.
  • Bolted joints: the clamping counter-face on studs and bolts across every assembly type.
  • Vibration-prone equipment: where a locking or flanged style resists loosening.
  • Frames & weldments: captive or welded options for repeatable assembly.
  • General machine building: fastening covers, brackets, motors and sub-assemblies on production equipment.

How to Specify All-Metal Hex Flange Lock Nuts for Your Application

  • Size: Match the nominal size to the mating thread or hole. This product spans 8 mm–12 mm; check the full table below for the exact dimensions of each size.
  • Locking & grade: Match the strength grade to the bolt, and choose a locking style (nyloc, all-metal, serrated flange) if the joint sees vibration.
  • Environment: For damp, coastal or chemical exposure prefer A4/316 stainless or a suitable coating; indoors, plated steel or A2 is usually sufficient.
  • Standard: This product is supplied to GB/T 6187 / DIN 6927 / ASME B18.2.2. Quoting the standard on your order guarantees interchangeable dimensions between suppliers.

Installation & Assembly Practice

  • Run the nut down by hand before applying the wrench to catch cross-threading early.
  • Tighten the nut rather than the bolt head where access allows — the torque-to-preload relation is more consistent.
  • For locking styles, note that nyloc inserts are single-use in critical joints and lose grip above roughly 120 °C.

Common Selection Mistakes with All-Metal Hex Flange Lock Nuts

  • Pairing a high-class bolt with a lower-class nut — the nut strips before the bolt reaches proof load; the nut class must meet or exceed the bolt class.
  • Using a plain nut with a spring washer in severe vibration instead of a prevailing-torque locking nut.
  • Re-using nyloc nuts in critical joints.

Where All-Metal Hex Flange Lock Nuts Are Not the Right Choice

Not on their own — they need a matching bolt or stud — and a plain nut is not a substitute for a locking type under heavy vibration.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (GB/T 6187 / DIN 6927 / ASME B18.2.2)

Strength classMaterialLocking methodFinish optionsService
8carbon steeldeformed all-metal threadblack oxide or zincgeneral vibration-exposed joints
10carbon steel or alloy steeldeformed all-metal threadblack oxide or zinchigher-preload vibration service
12alloy steeldeformed all-metal threadblack oxide or zinchigh-temperature and high-preload service
Inside the plant

Manufactured in our own plant

This part is cold-formed, threaded, heat-treated and finished in-house. The stages below are where its class and finish are actually decided.

  1. Wire rod feeding into a cold heading machine
    01

    Cold heading

    Wire rod is drawn to size and cold-formed into blanks. Forming rather than cutting keeps the grain flow continuous around the head, which is where a bolt is most likely to fail.

    Head dimensions and under-head radius checked at set-up and per shift.

  2. Thread rolling machine producing bolt threads
    02

    Thread rolling

    Threads are rolled between hardened dies rather than cut. Rolled threads are stronger in fatigue than cut threads and hold pitch and flank angle far more consistently across a batch.

    Go / no-go ring gauges to ISO 965 tolerance class 6g.

  3. Baskets of bolts staged for heat treatment
    03

    Heat treatment

    Quench-and-temper brings carbon and alloy steel to the property class ordered — 8.8, 10.9 or 12.9 — with the furnace charge tracked so a finished lot can be traced back to it.

    Core hardness and tensile tested per lot to ISO 898-1.

  4. Zinc plated bolts in a treatment basket
    04

    Surface treatment

    Zinc, zinc-nickel, hot-dip galvanizing, black oxide, phosphate and Dacromet, selected against the service environment rather than against the price list.

    Coating thickness and neutral salt spray hours to ISO 9227.

Frequently Asked Questions

How do I choose the right size of All-Metal Hex Flange Lock Nuts?

Match the nominal size to the mating thread or hole. This product is available from 8 mm to 12 mm; the full dimension table on this page lists each size.

Do All-Metal Hex Flange Lock Nuts need a locking feature?

If the joint sees vibration or cyclic load, use a locking style (nyloc, all-metal lock, or serrated flange) or a thread-locking adhesive. For static joints a standard nut tightened correctly is usually sufficient.

What material should All-Metal Hex Flange Lock Nuts be for outdoor use?

For damp, coastal or chemical environments specify A4 (316) stainless or a suitably coated steel. For indoor or dry use, A2 (304) stainless or zinc-plated steel is normally adequate.

Are All-Metal Hex Flange Lock Nuts made to a recognized standard?

Yes — they are manufactured to GB/T 6187 / DIN 6927 / ASME B18.2.2, so dimensions are interchangeable between suppliers when you quote the standard on your order.

Can I get a quote for All-Metal Hex Flange Lock Nuts in the size and material I need?

Yes. Use the technical drawing and quote form on this page to set the size and options, then send the exact configuration to our team for pricing and lead time.