Dimensional data for M6 U-Bolts to Industry standard, with the installation notes for this type. Values are taken from the governing standard rather than from a general machine-thread table, because this type is not selected on one.
M6 Dimensional Row (Industry standard)
| Thread size | Pitch (mm) | Inside width A (mm) | Inside height / leg length B (mm) | Pipe size ref | Thread length (mm) | Reference standard | Notes |
|---|---|---|---|---|---|---|---|
| M6 | 1.0 | 27 | 60 | 3/4 in | 25 | Industry standard | Round-bend U-bolt with 2 nuts |
Tightening Torque for M6
| Class 8.8 (dry, ~µ 0.125) | ≈ 10 Nm |
|---|---|
| Class 10.9 (dry, ~µ 0.125) | ≈ 14 Nm |
| Class 12.9 (dry, ~µ 0.125) | ≈ 17 Nm |
Indicative dry-joint values. Lubrication can lower the required torque by 15–25%. Always confirm against the joint design, especially when going up a strength class.
Proof Load & Strength for M6
| Tensile stress area As (ISO 898-1) | 20.1 mm² |
|---|---|
| Proof load, class 8.8 | 12 kN |
| Proof load, class 10.9 | 17 kN |
| Proof load, class 12.9 | 19 kN |
| Min. ultimate tensile, class 8.8 | 16 kN |
Proof load = stress area × proof stress per ISO 898-1. Design joints so the working preload stays below the proof load of the selected class.
Common Applications for M6 U-Bolts
M6 U-Bolts are commonly specified for general-purpose machinery, jigs, fixturing and light structural connections.
Mating Parts for M6
For M6, pair with a M6 hex nut (ISO 4032 / DIN 934) and, where used, a M6 flat washer (ISO 7089 / DIN 125A) under the head and under the nut.
When to Step Up or Down from M6
When the joint preload approaches the proof load of M6 class 8.8, step up to M8 class 8.8 (or move to M6 class 10.9). When the joint is over-specified, M5 often saves weight and cost without losing the safety margin.