Temperature range, chemical and fluid compatibility, hardness and the full dimensional range for this compound.

FKM (Viton®-type) Anaerobic Threadlockers and Thread Sealants are supplied to fluoroelastomer, typically 75 Shore A. Corrosion behaviour is excellent resistance to heat, fuels, and most chemicals; poor with ketones and hot water/steam, the material is non-magnetic, and the usable service range is approx. -20 °C to +200 °C. In practice this grade is specified where temperature or chemical exposure exceeds nitrile.

Grade
fluoroelastomer, typically 75 Shore A
Corrosion resistance
Excellent resistance to heat, fuels, and most chemicals; poor with ketones and hot water/steam
Magnetic response
Non-magnetic
Service temperature
approx. -20 °C to +200 °C

Property values are typical for the grade. Certified mechanical test data is available on request for production orders.

FKM (Viton®-type) Anaerobic Threadlockers and Thread Sealants reference image

Material specification page for anaerobic threadlockers and thread sealants in FKM (Viton®-type). Covers the grade designation (fluoroelastomer, typically 75 Shore A), corrosion and magnetic behavior, comparable grades and their trade-offs, and the sizes available to Trade series (anaerobic adhesives for threaded assemblies).

Why Choose FKM (Viton®-type) for Anaerobic Threadlockers and Thread Sealants

Specified where temperature or chemical exposure exceeds nitrile. For anaerobic threadlockers and thread sealants, this matters when excellent resistance to heat, fuels, and most chemicals; poor with ketones and hot water/steam is the primary requirement.

Mechanical & Physical Properties

Grade designationfluoroelastomer, typically 75 Shore A
Magnetic responseNon-magnetic
Service temperatureapprox. -20 °C to +200 °C
Corrosion characteristicExcellent resistance to heat, fuels, and most chemicals; poor with ketones and hot water/steam

Corrosion Behavior in Service

Carbon and alloy steel anaerobic threadlockers and thread sealants require a coating for corrosion protection. Zinc plating (with or without passivation) is the most common; hot-dip galvanizing is used for outdoor structural service; black-oxide is mainly a tarnish-prevention finish for tool-room use.

Comparable Grades

For anaerobic threadlockers and thread sealants, consider NBR where the service is ordinary mineral oil and the cost matters, or EPDM for hot water and steam, which attacks FKM. Elastomer selection is decided by the medium, the temperature range and whether the seal is static or dynamic — not by strength.

Sizes of Anaerobic Threadlockers and Thread Sealants Available in FKM (Viton®-type)

GradeRemovalTypical useNotes
low strengthhand toolsset screws, adjusting screws, small fastenersup to about M12
medium strengthhand toolsgeneral assembly, machine screwsthe usual default
high strengthheat and hand toolsstuds, permanent assembliesnot for parts serviced in the field
thread sealant gradehand toolstapered pipe threads, hydraulic fittingsseals rather than locks
retaining compoundheatbearings, bushes, cylindrical fitsnot a thread product

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (Trade series (anaerobic adhesives for threaded assemblies))

GradeRemovalTypical useNotes
low strengthhand toolsset screws, adjusting screws, small fastenersup to about M12
medium strengthhand toolsgeneral assembly, machine screwsthe usual default
high strengthheat and hand toolsstuds, permanent assembliesnot for parts serviced in the field
thread sealant gradehand toolstapered pipe threads, hydraulic fittingsseals rather than locks
retaining compoundheatbearings, bushes, cylindrical fitsnot a thread product

Applications & Industries

Anaerobic Threadlockers and Thread Sealants are bought for a small number of well-defined jobs. These are the ones we ship them for. Stocked from low strength to retaining compound (inside diameter).

Industries that specify Anaerobic Threadlockers and Thread Sealants

  • Field maintenance Securing set screws.
  • Machine assembly Fasteners that must not loosen.
  • Automotive Vibration-prone joints.
  • Hydraulics Tapered thread sealing.
  • Process & food equipment Sealing at joints that are cleaned and inspected.
  • Hydraulics & pneumatics Static and dynamic sealing in cylinders and valve bodies.

Typical applications

  • allowing the stated cure time before loading the joint
  • choosing the grade by how the joint will be serviced
  • degreasing both threads before applying
  • using a sealant grade rather than a locking grade on pipe threads
  • excluding dust and moisture from a housing
  • sealing a joint against fluid or air pressure

Service conditions to specify against

Sealed joints
Used where the fixing has to keep water or air out as well as hold — the elastomer, not the fastener, decides service life.
Vibration
Specified where cyclic load would loosen a plain nut or screw — rotating plant, rail, mobile equipment and anything that is not re-torqued in service.

Where to use something else

  • Do not use a high-strength grade on anything that will be serviced in the field; removing it needs heat, and heat is rarely available where the fastener has to come out.

Full application guide: where Anaerobic Threadlockers and Thread Sealants are used, how to specify them, and the cases they are wrong for

Inside the plant

Manufactured in our own plant

This part is cold-formed, threaded, heat-treated and finished in-house. The stages below are where its class and finish are actually decided.

  1. Wire rod feeding into a cold heading machine
    01

    Cold heading

    Wire rod is drawn to size and cold-formed into blanks. Forming rather than cutting keeps the grain flow continuous around the head, which is where a bolt is most likely to fail.

    Head dimensions and under-head radius checked at set-up and per shift.

  2. Thread rolling machine producing bolt threads
    02

    Thread rolling

    Threads are rolled between hardened dies rather than cut. Rolled threads are stronger in fatigue than cut threads and hold pitch and flank angle far more consistently across a batch.

    Go / no-go ring gauges to ISO 965 tolerance class 6g.

  3. Baskets of bolts staged for heat treatment
    03

    Heat treatment

    Quench-and-temper brings carbon and alloy steel to the property class ordered — 8.8, 10.9 or 12.9 — with the furnace charge tracked so a finished lot can be traced back to it.

    Core hardness and tensile tested per lot to ISO 898-1.

  4. Zinc plated bolts in a treatment basket
    04

    Surface treatment

    Zinc, zinc-nickel, hot-dip galvanizing, black oxide, phosphate and Dacromet, selected against the service environment rather than against the price list.

    Coating thickness and neutral salt spray hours to ISO 9227.

Frequently Asked Questions

Which finish is best for outdoor Anaerobic Threadlockers and Thread Sealants?

For outdoor service in steel, hot-dip galvanizing gives the longest life; zinc-flake (Geomet/Delta-Tone family) gives a thinner film with excellent salt-spray performance; standard zinc plating is the lowest-cost option for general indoor / shielded outdoor use.

What's the service temperature limit for FKM (Viton®-type)?

The practical service range is approx. -20 °C to +200 °C.

Can FKM (Viton®-type) replace stainless steel structurally?

No — stainless A2/A4 cannot match class 10.9 / 12.9 strength. Stainless is selected for corrosion, not raw strength.

Are FKM (Viton®-type) Anaerobic Threadlockers and Thread Sealants magnetic?

FKM (Viton®-type) Anaerobic Threadlockers and Thread Sealants are non-magnetic.

How do I request a quotation?

Use the technical drawing on this page to pick the exact configuration, then submit it with the quote form. We respond within one business day.