Temperature range, chemical and fluid compatibility, hardness and the full dimensional range for this compound.

NBR (Nitrile) Anaerobic Threadlockers and Thread Sealants are supplied to acrylonitrile-butadiene rubber, typically 70 Shore A. Corrosion behaviour is good resistance to mineral oil, grease and hydraulic fluid; poor in ozone and weathering, the material is non-magnetic, and the usable service range is approx. -30 °C to +100 °C. In practice this grade is the default elastomer for oil and hydraulic sealing.

Grade
acrylonitrile-butadiene rubber, typically 70 Shore A
Corrosion resistance
Good resistance to mineral oil, grease and hydraulic fluid; poor in ozone and weathering
Magnetic response
Non-magnetic
Service temperature
approx. -30 °C to +100 °C

Property values are typical for the grade. Certified mechanical test data is available on request for production orders.

NBR (Nitrile) Anaerobic Threadlockers and Thread Sealants reference image

Anaerobic Threadlockers and Thread Sealants manufactured in NBR (Nitrile) (acrylonitrile-butadiene rubber, typically 70 Shore A) are dimensioned to Trade series (anaerobic adhesives for threaded assemblies). The sections below give the mechanical and physical properties of the grade, its behavior in corrosive and elevated-temperature service, and the full size table.

Why Choose NBR (Nitrile) for Anaerobic Threadlockers and Thread Sealants

The default elastomer for oil and hydraulic sealing. For anaerobic threadlockers and thread sealants, this matters when good resistance to mineral oil, grease and hydraulic fluid; poor in ozone and weathering is the primary requirement.

Mechanical & Physical Properties

Grade designationacrylonitrile-butadiene rubber, typically 70 Shore A
Magnetic responseNon-magnetic
Service temperatureapprox. -30 °C to +100 °C
Corrosion characteristicGood resistance to mineral oil, grease and hydraulic fluid; poor in ozone and weathering

Corrosion Behavior in Service

Carbon and alloy steel anaerobic threadlockers and thread sealants require a coating for corrosion protection. Zinc plating (with or without passivation) is the most common; hot-dip galvanizing is used for outdoor structural service; black-oxide is mainly a tarnish-prevention finish for tool-room use.

Comparable Grades

For anaerobic threadlockers and thread sealants, consider FKM where temperature or chemical exposure is higher, or EPDM where the medium is water, steam or brake fluid rather than oil. Elastomer selection is decided by the medium, the temperature range and whether the seal is static or dynamic — not by strength.

Sizes of Anaerobic Threadlockers and Thread Sealants Available in NBR (Nitrile)

GradeRemovalTypical useNotes
low strengthhand toolsset screws, adjusting screws, small fastenersup to about M12
medium strengthhand toolsgeneral assembly, machine screwsthe usual default
high strengthheat and hand toolsstuds, permanent assembliesnot for parts serviced in the field
thread sealant gradehand toolstapered pipe threads, hydraulic fittingsseals rather than locks
retaining compoundheatbearings, bushes, cylindrical fitsnot a thread product

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (Trade series (anaerobic adhesives for threaded assemblies))

GradeRemovalTypical useNotes
low strengthhand toolsset screws, adjusting screws, small fastenersup to about M12
medium strengthhand toolsgeneral assembly, machine screwsthe usual default
high strengthheat and hand toolsstuds, permanent assembliesnot for parts serviced in the field
thread sealant gradehand toolstapered pipe threads, hydraulic fittingsseals rather than locks
retaining compoundheatbearings, bushes, cylindrical fitsnot a thread product

Applications & Industries

Anaerobic Threadlockers and Thread Sealants are bought for a small number of well-defined jobs. These are the ones we ship them for. Stocked from low strength to retaining compound (inside diameter).

Industries that specify Anaerobic Threadlockers and Thread Sealants

  • Field maintenance Securing set screws.
  • Machine assembly Fasteners that must not loosen.
  • Automotive Vibration-prone joints.
  • Hydraulics Tapered thread sealing.
  • Process & food equipment Sealing at joints that are cleaned and inspected.
  • Hydraulics & pneumatics Static and dynamic sealing in cylinders and valve bodies.

Typical applications

  • allowing the stated cure time before loading the joint
  • choosing the grade by how the joint will be serviced
  • degreasing both threads before applying
  • using a sealant grade rather than a locking grade on pipe threads
  • excluding dust and moisture from a housing
  • sealing a joint against fluid or air pressure

Service conditions to specify against

Sealed joints
Used where the fixing has to keep water or air out as well as hold — the elastomer, not the fastener, decides service life.
Vibration
Specified where cyclic load would loosen a plain nut or screw — rotating plant, rail, mobile equipment and anything that is not re-torqued in service.

Where to use something else

  • Do not use a high-strength grade on anything that will be serviced in the field; removing it needs heat, and heat is rarely available where the fastener has to come out.

Full application guide: where Anaerobic Threadlockers and Thread Sealants are used, how to specify them, and the cases they are wrong for

Inside the plant

Manufactured in our own plant

This part is cold-formed, threaded, heat-treated and finished in-house. The stages below are where its class and finish are actually decided.

  1. Wire rod feeding into a cold heading machine
    01

    Cold heading

    Wire rod is drawn to size and cold-formed into blanks. Forming rather than cutting keeps the grain flow continuous around the head, which is where a bolt is most likely to fail.

    Head dimensions and under-head radius checked at set-up and per shift.

  2. Thread rolling machine producing bolt threads
    02

    Thread rolling

    Threads are rolled between hardened dies rather than cut. Rolled threads are stronger in fatigue than cut threads and hold pitch and flank angle far more consistently across a batch.

    Go / no-go ring gauges to ISO 965 tolerance class 6g.

  3. Baskets of bolts staged for heat treatment
    03

    Heat treatment

    Quench-and-temper brings carbon and alloy steel to the property class ordered — 8.8, 10.9 or 12.9 — with the furnace charge tracked so a finished lot can be traced back to it.

    Core hardness and tensile tested per lot to ISO 898-1.

  4. Zinc plated bolts in a treatment basket
    04

    Surface treatment

    Zinc, zinc-nickel, hot-dip galvanizing, black oxide, phosphate and Dacromet, selected against the service environment rather than against the price list.

    Coating thickness and neutral salt spray hours to ISO 9227.

Frequently Asked Questions

What's the service temperature limit for NBR (Nitrile)?

The practical service range is approx. -30 °C to +100 °C.

Can NBR (Nitrile) replace stainless steel structurally?

No — stainless A2/A4 cannot match class 10.9 / 12.9 strength. Stainless is selected for corrosion, not raw strength.

Are NBR (Nitrile) Anaerobic Threadlockers and Thread Sealants magnetic?

NBR (Nitrile) Anaerobic Threadlockers and Thread Sealants are non-magnetic.

What corrosion resistance do NBR (Nitrile) Anaerobic Threadlockers and Thread Sealants offer?

NBR (Nitrile) Anaerobic Threadlockers and Thread Sealants provide good resistance to mineral oil, grease and hydraulic fluid; poor in ozone and weathering with a service range of approx. -30 °C to +100 °C.

How do I request a quotation?

Use the technical drawing on this page to pick the exact configuration, then submit it with the quote form. We respond within one business day.