This page covers M30 Hex Bolts, Grade C to ISO 4016: the full dimensional row, hole and tool sizes, proof-load data and typical applications. All values are taken from the governing standards (ISO 4016 together with ISO 273, ISO 724 and ISO 898-1 where applicable).
M30 Dimensional Row (ISO 4016)
| Size | Pitch (mm) | Width across flats s (mm) | Width across corners e min (mm) | Head height k (mm) | Product grade | Reference standard |
|---|---|---|---|---|---|---|
| M30 | 3.5 | 46.0 | 50.85 | 19.75 | Grade C | ISO 4016 / DIN 601 |
Spanner & Drive for M30 Hex Bolts, Grade C
M30 Hex Bolts, Grade C have a width across flats of 46.0 mm — fit a 46.0 mm open-ended spanner or socket. Use a 6-point socket for tight clearances and to reduce rounding; for repeated assembly choose a torque wrench so the joint preload is repeatable.
Hole Sizes for M30
| Coarse-thread pitch (ISO 724) | 3.5 mm |
|---|---|
| Through-hole / clearance (ISO 273 medium) | 33 mm |
| Tapping drill, coarse thread | 26.5 mm |
Tightening Torque for M30
| Class 8.8 (dry, ~µ 0.125) | ≈ 1400 Nm |
|---|---|
| Class 10.9 (dry, ~µ 0.125) | ≈ 2000 Nm |
| Class 12.9 (dry, ~µ 0.125) | ≈ 2400 Nm |
Indicative dry-joint values. Lubrication can lower the required torque by 15–25%. Always confirm against the joint design, especially when going up a strength class.
Proof Load & Strength for M30
| Tensile stress area As (ISO 898-1) | 561 mm² |
|---|---|
| Proof load, class 8.8 | 337 kN |
| Proof load, class 10.9 | 466 kN |
| Proof load, class 12.9 | 544 kN |
| Min. ultimate tensile, class 8.8 | 449 kN |
Proof load = stress area × proof stress per ISO 898-1. Design joints so the working preload stays below the proof load of the selected class.
Common Applications for M30 Hex Bolts, Grade C
M30 Hex Bolts, Grade C are commonly specified for structural steelwork, heavy machinery foundations and large flange joints.
Installation Tips for M30 Hex Bolts, Grade C
- Use a 6-point socket where access allows — 12-point sockets are more prone to rounding the corners on smaller sizes.
- On flanged or serrated variants, do NOT add a separate flat washer — the flange already spreads the load and the washer can defeat the locking serrations.
- At M30 the stretch in the bolt becomes the controlling factor — for critical joints, use angle-controlled or stretch-controlled tightening instead of pure torque.
Mating Parts for M30
For M30, pair with a M30 hex nut (ISO 4032 / DIN 934) and, where used, a M30 flat washer (ISO 7089 / DIN 125A) under the head and under the nut.